摘要: 运用微波消解-原子荧光法联测海洋生物体中砷和汞,对仪器条件、消解体系、还原剂硼氢化钾浓度等进行优化,消除NO2-对测定的干扰。此法砷和汞的检测限分别为0.02mg/Kg和0.002 mg/Kg;相对标准偏差分别为2.83%和2.05%;通过分析验证该方法简单、灵敏,结果可靠,可用于海洋生物体中砷和汞联测。

关键词: 微波消解-原子荧光法, 联测, 砷和汞, microwave digestion-atomic fluorescence spectrometry, simultaneous determination, arsenic and mercury

Abstract: The method was presented for the simultaneous determination of arsenic and mercury in marine organism by microwave digestion-atomic fluorescence spectrometry.The influence of instrument parameters,digestive system, KBH4 concentration were optimized.The influence of NO2- was avoided.The developed method showed limits of detection of 0.02mg/Kg for arsenic , 0.002 mg/Kg for mercury and relative deviatiaons of 2.83% for arsenic ,2.05% for mercury.The method,its simplicity,sensitivity and reliability,has good suitability for the simultaneous determination of arsenic and mercury in marine organism.