气相色谱-质谱法测定甲壳类水产品中4-己基间苯二酚残留

    Determination of 4-hexylresorcinol residue in crustacea by gas chromatography-mass spectrometry

    • 摘要: 研究建立了甲壳类水产品中4-己基间苯二酚(4-hexylresorcinol,4-HR)残留量的固相萃取-气相色谱-质谱检测方法。样品采用乙酸乙酯提取,硅胶柱净化,乙酸乙酯洗脱,气相色谱-质谱测定,外标法定量。4-HR的响应值与其质量浓度在0.05~10μg/m L范围内的线性关系良好,相关系数为0.9 997;0.05~1 mg/kg添加浓度的日内和日间平均回收率为76.8%102%,相对标准偏差为2.43%7.65%;检出限为0.01 mg/kg,最低定量限为0.05 mg/kg。该方法适用于甲壳类水产品中4-HR残留的检测。

       

      Abstract: Gas chromatography-mass spectrometry (GC-MS) coupled with solid-phase extraction was developed for determination of 4-hexylresorcinol residue in crustacean. The 4-HR was extracted with ethyl acetate, purified by silicagel column and eluted with ethyl acetate, the eluent was concentrated and dissolved in ethyl acetate-n-hexane(1:1,v/v), then analyzed by gas chromatography-mass spectrometry. The results showed that the linear range was 0.05 ~10 μg/mL and its correlation coefficient was 0.9 997.When spiked within 0.05~1 mg/kg, the average recoveries of intraday and intraday were 76.8%~102%, and their relative standard deviations were 2.43%~7.65%.The limits of detection and limits of quantitation were 0.01 mg/kg and 0.05 mg/kg, respectively. This method can be applied to determine the 4-HR residues in crustacea with the advantages of high extraction efficiency, high purification effect and less solvent consumption.

       

    /